1350-O/H19 알루미늄 와이어

1350 aluminum wire is the industry-standard Electrical Conductor (EC) grade, with a minimum aluminum content of 99.50% and guaranteed electrical conductivity of 61.8% IACS. This non-heat-treatable alloy is designed specifically for maximum conductivity in power transmission, cable manufacturing, and electrical applications. Linsy supplies 1350 aluminum wire in O (annealed) and H19 (full-hard) tempers, with diameters from 0.8 mm to 30 mm, custom sizes available, MTC reports provided, and SGS test reports available on request.

Available form: wire / coil
흔히 나타나는 기질: O / H19
Diameter range: 0.8 – 30 mm
처리 지원: custom drawing / coil packaging / cut-to-length
품질 관련 문서: MTC report with every order, SGS test reports on request

What Is 1350 Aluminum Wire?

1350 aluminum wire (UNS A91350, EN AW-1350 / Al99.5EC) is a commercially pure aluminum alloy specifically designated as the Electrical Conductor (EC) grade. With a minimum aluminum content of 99.50%, 1350 achieves a guaranteed minimum electrical conductivity of 61.8% IACS (International Annealed Copper Standard), making it the benchmark alloy for electrical conductor applications worldwide.

As a non-heat-treatable 1xxx series alloy, 1350 derives its mechanical strength entirely from cold working. In the O (annealed) temper, 1350 wire is extremely soft and ductile—ideal for maximum formability in drawing, bending, and winding operations. In the H19 (full-hard) temper, strain hardening raises tensile strength to approximately 150–200 MPa while still retaining the alloy’s characteristic high conductivity, making H19 wire suitable for overhead power conductors and high-strength cable cores.

1350 aluminum wire is governed primarily by ASTM B230 (Aluminum Wire, 1350 for Electrical Purposes) and ASTM B233 (Aluminum Bus Conductor Wire). It is also covered under ISO 6361, EN 573-3, and various Chinese national standards including GB/T 3190 and JB 2053. Linsy supplies 1350 aluminum wire in diameters from 0.8 mm to 30 mm, with custom sizes available upon request.

1350 Aluminum Wire Specifications

사용 가능한 템퍼

성질 Condition 일반적인 사용
O Annealed (fully soft) Maximum formability, drawing, coil winding, flexible conductors
H19 Strain hardened to full hard Overhead power conductors, high-strength cable cores, busbars

Wire Diameter Range

사양 가치
Diameter range 0.8 – 30 mm
Diameter tolerance Per ASTM B230 grade requirements
코일 중량 Minimum 50 kg per coil
Surface finish Mill finish / bright drawn (options available)
포장 Coiled, wooden pallet or custom packaging

Equivalent Designations & Standards

Designation System Equivalent
UNS A91350
EN AW EN AW-1350 / Al99.5EC
AA (알루미늄 협회) 1350
JIS A1350
GB (중국) 1A35 / 1350 (per GB/T 3190)
ISO Al 99.5EC

Applicable Standards

표준 Title / Scope
ASTM B230 Aluminum Wire, 1350 for Electrical Purposes
ASTM B233 Aluminum Bus Conductor Wire (1350)
ASTM B209 Aluminum and Aluminum-Alloy Sheet and Plate (general reference)
ISO 6361 Wrought Aluminum and Aluminum Alloy — Sheet, Strip and Plate
EN 573-3 Aluminum and Aluminum Alloys — Chemical Composition and Form of Wrought Products
GB/T 3190 Wrought Aluminum and Aluminum Alloy Chemical Composition
JB 2053 Aluminum Wire for Electrical Purposes (Chinese industry standard)

1350 알루미늄의 화학 성분

요소 Min % Max %
실리콘(Si) 0.10
철(Fe) 0.40
구리(Cu) 0.05
망간(Mn) 0.01
마그네슘(Mg) 0.01
크롬(Cr) 0.01
아연(Zn) 0.05
티타늄(Ti) 0.02
Others: each 0.03
Others: total 0.10
알루미늄(Al) 99.50 잔액

열처리 상태에 따른 기계적 특성

속성 1350-O Wire 1350-H19 Wire
Tensile strength, ultimate (MPa) 60 – 100 150 – 200
Tensile strength, yield (MPa) 20 – 50 145 – 185
Elongation at break (%) ≥ 20 ≥ 1.5
Electrical conductivity (% IACS) ≥ 61.8 ≥ 61.8
Thermal conductivity (W/(m·K)) 234 225

템퍼 선택 가이드

성질 주요 이점 일반적인 애플리케이션 When to Choose
O(어닐링) Maximum ductility and formability; highest conductivity Magnet wire, coil windings, flexible conductors, fine-diameter drawing When you need the softest wire for drawing, winding, or bending into tight configurations
H19 (Full Hard) High tensile strength with retained conductivity Overhead power conductors (ACSR core wire), busbars, high-strength cable cores When you need strength for overhead spans or structural conductor applications where formability is not the primary concern

Key Characteristics of 1350 Aluminum

전기 전도성

1350 aluminum is the designated EC (Electrical Conductor) grade, with a guaranteed minimum conductivity of 61.8% IACS. This makes 1350 the most conductive aluminum alloy commonly available for wire and conductor applications. The conductivity remains consistent across both O and H19 tempers, ensuring that strength selection does not compromise electrical performance.

내식성

The high purity of 1350 (≥99.50% Al) provides excellent corrosion resistance in most atmospheric and mildly chemical environments. The naturally forming aluminum oxide surface layer protects the wire from further oxidation, making 1350 suitable for outdoor overhead conductor applications and exposed electrical installations without additional protective coating.

성형성 및 용접성

In the O temper, 1350 wire is extremely formable—suitable for deep drawing, bending, and fine-gauge winding. Even in H19 temper, 1350 retains moderate formability for coiling and stranding operations. 1350 aluminum has good weldability by resistance welding (suitable for conductor splicing) and can be joined by MIG/TIG welding with appropriate filler wire, though welding is uncommon in standard conductor manufacturing.

일반적인 애플리케이션

Industry / Application Typical Uses Why 1350 Is Used
Power transmission & distribution Overhead conductors (ACSR, AAC), underground cable cores Maximum conductivity at lowest weight; H19 temper provides span strength
Electrical equipment manufacturing Magnet wire, coil windings, transformer windings O temper allows fine drawing and tight winding without breakage
Bus conductor systems High-voltage busbars, switchgear conductors, grounding wire High conductivity with adequate mechanical strength in H19
Wire & cable manufacturing Bare aluminum wire, stranded conductors, cable shielding EC grade designation ensures compliance with ASTM B230 conductivity requirements
Heat dissipation Heat sink wire, thermal conductor elements High thermal conductivity (225–234 W/(m·K)) transfers heat efficiently

가공 및 표면 마감 참고 사항

1350 aluminum wire is typically supplied in mill-finish or bright-drawn surface condition. Additional surface options include:

  • Bright drawn: Smooth surface for conductor applications where surface quality affects electrical contact
  • Mill finish: Standard surface for general-purpose wire
  • 양극 산화 처리: Possible for corrosion enhancement in exposed installations, though rarely required due to 1350’s natural oxide protection
  • Custom packaging: Coiled, spooled, or cut-to-length per project requirements

Linsy supports custom wire drawing to specific diameters and coil packaging configurations. For overhead conductor applications, wire can be supplied in long continuous coils with controlled spooling to minimize handling damage.

품질 문서 및 검사

Every 1350 aluminum wire order from Linsy includes the following quality documentation:

  • MTC (Material Test Certificate): Issued per order, confirming chemical composition and mechanical properties
  • Dimensional inspection: Diameter tolerance verified per ASTM B230 grade requirements
  • Conductivity verification: % IACS values documented on MTC for conductor-grade orders

For customers requiring additional third-party verification, SGS test reports are available on request (at an extra testing cost), covering:

  • SGS 화학 성분 분석 보고서
  • SGS 기계적 특성 보고서
  • SGS 치수 검사 보고서

Why Choose Linsy for 1350 Aluminum Wire

Linsy Aluminum supplies 1350 EC-grade aluminum wire with over 20 years of manufacturing and sourcing experience. Our supply model combines inventory availability with low-MOQ custom production, covering both standard conductor specifications and project-specific requirements.

We provide:

  • Both O and H19 tempers in diameters from 0.8 mm to 30 mm, with custom sizes available
  • 모든 주문 시 MTC 보고서 제공 confirming chemical composition, mechanical properties, and conductivity
  • ISO 9001, ISO 14001, and ISO 45001 certified quality management
  • SGS test reports available on request for third-party verification
  • Custom drawing and packaging options for project-specific wire specifications
  • Low MOQ for custom orders with lead times of 10–60 days depending on specifications
  • Delivery to 20+ countries with export packaging and documentation support

관련 자료

1350 Aluminum Wire FAQ

What is 1350 aluminum wire used for?

1350 aluminum wire is primarily used in electrical conductor applications, including overhead power transmission conductors (AAC, ACSR core wire), magnet wire for transformer and motor windings, bus conductor systems, and cable manufacturing. Its guaranteed 61.8% IACS conductivity makes it the standard EC-grade wire alloy.

What is the difference between 1350-O and 1350-H19 wire?

1350-O (annealed) wire is fully soft with tensile strength of 60–100 MPa and elongation ≥20%, making it ideal for fine drawing and coil winding. 1350-H19 (full-hard) wire has tensile strength of 150–200 MPa and elongation ≥1.5%, suited for overhead conductor spans where mechanical strength is required. Both tempers maintain the same 61.8% IACS minimum conductivity.

How does 1350 aluminum conductivity compare to copper?

1350 aluminum has a minimum conductivity of 61.8% IACS, compared to pure copper at 100% IACS. However, when adjusted for weight, an aluminum conductor can carry the same current as copper at roughly half the weight, making 1350 aluminum wire the preferred choice for overhead power transmission where weight savings are critical.

What standards govern 1350 aluminum wire?

1350 aluminum wire is governed primarily by ASTM B230 (Aluminum Wire, 1350 for Electrical Purposes) and ASTM B233 (Aluminum Bus Conductor Wire). Other applicable standards include ISO 6361, EN 573-3, GB/T 3190, and JB 2053.

Can 1350 aluminum wire be welded?

1350 aluminum has good weldability by resistance welding (common for conductor splicing) and can be MIG/TIG welded with appropriate filler wire. However, welding is not typically required in standard conductor manufacturing, where mechanical splicing and compression connectors are more common.

Do you provide MTC for 1350 aluminum wire orders?

Yes. Linsy provides an MTC (Material Test Certificate) with every 1350 aluminum wire order, confirming chemical composition, mechanical properties, and conductivity values. SGS test reports are available on request for third-party verification.

What is the minimum order quantity for 1350 aluminum wire?

Linsy supports low MOQ orders for 1350 aluminum wire, including custom diameter and coil specifications. For standard sizes in stock, MOQ is typically one coil (minimum 50 kg). For custom specifications, lead times range from 10 to 60 days depending on diameter, temper, and order complexity.

생산 장비

인증

창고 및 재고

주문 프로세스

린시의 장점

린시 알루미늄은 항공우주, 일반 엔지니어링, 자동차, 해양, 조선 및 기타 특수 산업 분야를 포함한 다양한 산업 분야에 서비스를 제공하는 알루미늄 가공 제품의 선도적인 공급업체입니다.

당사는 인증에서 알 수 있듯이 최고 수준의 품질과 환경적 책임을 유지하기 위해 최선을 다하고 있습니다: ISO 9001:2008, ISO 14001:2004 및 SGS.

오늘 양식을 등록하세요! 린시 알루와 함께 프리미엄 알루미늄 솔루션을 만나보세요.

WhatsApp 전화